Căutare

* Electronic Bidding * - * Electronic Budgeting * Vibration Drug Sensor Bearing: Vibration/Health Measurement Sensor With The Following Technical Specifications: Triaxial Vibration Meter For Rotary Machine Rolling Inspection, Compatible With Android/Ios Standard Devices. And Demodulated Acceleration Def Factory/Envelope Or Peakvue Intended For Rolling Failure Detection Should Have The Following Functions: Color Guided Diagnosis Indicating Failure Severity; Spectrum Access To The Result Of Listening To Bearing By Bluetooth Headset; Berry Bearing For Better Diagnosis; Inspected; Constructive Characteristics: -Clobe: Stainless Steel-Protection: Ip65-Debate: Internal Battery Battery Ion Battery Drive: 8 Hours-Operational Time: -20 ° C Up To 60 ° C-Shock Resistance: Peak 5,000 G-Continuous Vibration: Peak 500 G Technical Specifications: Tri-Axial Messations: Y And Z-Family Sampling: 51.2 Khz For All Freq Axes. Maximum 20Khz Vibration: Piezoelectric / Shear Mode Annular Sensor Annular Sensitivity, 24 ° C: 100Mv / G Numerical Conversion Sensitivity Setting: Calibration And Adjustment Of The Factory Factory: 80 G-Relations Signal Signal:> 80Db-Non-Linear: 1% Maximum.-Response At Frequency After Tri-Axial Mechanical Assembly- ± 3 Db Z: 0.4 Hz-15 Khz- ± 3 Db Xy: 0.4 Hz-6 Khz-Lavio Of Complete Band: 20 Khz On All Axes-Precision: +/- 5% @ 120 Hz, 1G Transverse Response 120Hz, 1G: 5% -26Db-Raw, Nominal: Bus-5 Khz: 5 Mg-> 1 Hz: 20? G/? Hz-Peak-Relief After 1 Signal Integration At Time: 0.13 Mm/S-Communication-Wireless Protocol: Wi-Fi Point To Point-Point Classic Wireless: Up To 25 Meters In Line With The Environment. Ios 9.3 Or More, Android 4.4.2 Or Most Supplier Shall Send, With The Proposal Of Supply, Official Commercial Catalog Of The Equipment Offered To Verify Compliance With The Required Specification. It Will Be Provided With A Technical Assistance Relationship Preferably In The State Of Minas Gerais. The Equipment Must Be Accompanied By A Guarantee Term Duly Completed In Portuguese Or Properly Translated; Manufacturing And Those Caused By Transportation When It Is The Responsibility Of The Supplier And Or Manufacturer. In The Act Of Receiving Inspection, The Instrument Must Be Within Factory Specifications And In Normal Operation. If The Equipment Is Not In Accordance With The Specifications Required And Defined By The Factory, The Supplier Will Perform Maintenance And New Calibration With The Issuance Of A Certificate Without Any Defective Labor And Defective Piece. (EXPIRED)

Cerere de oferte

Informaţii generale

   Aprilie 30, 2025
   Portugheză
   Altele
   publicat: Aprilie 30, 2025

Textul original

{"orgao": {"nome": "COPASA-Companhia de Saneamento de Minas Gerais ", "codigo": "", "cidade": "Belo Horizonte", "uf": "MG", "endereco": "Rua Carangola, 606 - T\u00e9rreo - Bairro Santo Ant\u00f4nio ", "telefone": [], "site": ""}, "objeto": " * Licita\u00e7\u00e3o Eletr\u00f4nica * - * Or\u00e7amenta\u00e7\u00e3o Eletr\u00f4nica * SENSOR DE MEDICAO DE VIBRACAO ROLAMENTOSEQUIPAMENTO: SENSOR DE...
Opţiuni de abonament

De bază

Complet

Corporate

$550 / an

$1000/an

Preț la cerere

Cumpăra Cumpăra Contactaţi-ne!
Va rugam sa retineti ca acest anunt este doar pentru informarea dv.
Facem toate eforturile pentru a avea cele mai complete si actuale informatii pe acest website, dar nu putem garanta ca toate informatiile oferite sunt corecte.
Daca aveti sugestii pentru actualizari/corectii pentru acest anunt, va rugam sa ne informati.